sisHYD User Guide

The ribbon Edit – Validation

  • Validate Network Data – Examines the network data in the active project for discrepancies. Incomplete information which was possibly caused by abort of inputs counts here, among other things. A part of the examination deals with the network topology in close proximity to pumps, in order to report parallel pipes which cannot be isolated, for example.
  • Validate Pipe Lengths – Starts the sisHYD assistant for examination and automatic correction of pipe lengths. See Update Pipe Lengths
  • Convert Customers to Consumers – Executes a conversion of all customer data to consumers.
  • This work step is no longer necessary due to the automation of the transformation. After the import of old data volumes, it is however still possible to force the synchronization manually.
  • Delete Customers – Starts the assistant to delete entire customer data including the consumers generated from it. See Delete customers.